Free Call Australia : 1 800 834 991

Related Products

Mirus GENLINK Dissimiliar Pitch Neutral Limiter

HIOKI 3257-50 Digital HiTester 
  • 3256-50: Average rectified type, AC voltage detection simply by placing the instrument close the insulated cable
  • 3256-50: Overload protect up to 600V for all measurement functions (V, O functions up to 1000V)
  • 3257-50: True RMS type, Duty ratio measurement for pulse signal analysis

Product Details

HIOKI 3257-50 Digital HiTester

Terminal shutter interlock mechanism for safety

3256-50: Average rectified type, AC voltage detection simply by placing the instrument close the insulated cable. 3256-50: Overload protect up to 600V for all measurement functions (V, O functions up to 1000V). 3257-50: True RMS type, Duty ratio measurement for pulse signal analysis. 3257-50: Overload protect up to 1000V for all measurement functions.

Regarding DMM Accuracy
Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.

DC Voltage : 420.0 mV to 1000 V, 5 ranges, Basic accuracy: ±0.5 % rdg. ±2 dgt.

AC Voltage /50 to 500 Hz 420.0 mV to 1000 V, 5 ranges, Basic accuracy: ±1.2 % rdg. ±3 dgt., (Average rectified) 420.0 mV to 1000 V, 5 ranges,

Resistance : 420.0 O to 42.00 MO, 6 ranges, Basic accuracy: ±0.7 % rdg. ±2 dgt.

DC Current : 42.00 µA to 420.0 mA, 10 A, 6 ranges, Basic accuracy: ±1.5 % rdg. ±4 dgt.

AC Current /50 to 500 Hz : 42.00 µA to 420.0 mA, 10 A, 6 ranges, Basic accuracy: ±2.5 % rdg. ±5 dgt., (Average rectified)

Hz (Frequency) : 199.99 Hz to 500.0 kHz, 5 ranges, Basic accuracy: ±0.02 % rdg. ±1 dgt., Input level: 0.8 V to 1000 V, 4 levels, Frequencies of less than 0.50 Hz cannot be measured

Duty ratio measure : Not available

Voltage Detection : Bring the top close to the power line, when the voltage is outside of the detection range, buzzer and the display blinks

Continuity buzzer : Threshold 50 O ± 40 O, Open terminal voltage: 3.4 V or less

Diode check : Open terminal voltage: 3.4 V or less, Testing current: 700 µA

Other function : Relative value, Memory, Auto power save, Auto hold, Recoding (Max./ Min. / Ave.)

Display : Digital/ LCD, max. 4200 digits (19999 digits at frequency measure)

Sample rate : 2.5 times/s (except Frequency), 5 times/s (Frequency, over 5 Hz), 25 times/s (Update of bar graph)

Power supply : Manganese battery (R03) ×2, Continuous use: 100 hours

Dimensions and mass : 76W (2.99in) × 167H (6.57in) × 33D (1.30in) mm, 260 g (9.2 oz)

Supplied accessories : TEST LEAD×1, Instruction Manual×1, Manganese batteries(R03)×2 (for trial purposes only), CARRYING CASE 9378×1

MIRUS Combined Neutral Current Eliminator (CNCE) A patented phase shifting autotransformer with a low zero sequence impedance at its output. When connected in series on a 3-phase, 4-wire ...
MIRUS Drive 24 Transformers Multiple output auto or isolation transformers ideally suited for reduction of harmonics generated by VFDs or other 3-phase rectifier loads. Drive 12/24â„¢ pr...
MIRUS 11-13 Neutral Current Eliminator 3-phase, 3-wire autotransformers with 30°, 15° or 20° phase shift between input and output. They are connected in series with the supply to variable...
MIRUS ULLTRA High Efficiency Transformers ULLTRA High Performance transformers are designed to deliver more energy savings than any other transformer on the market. The result is a high p...
MIRUS Neutral Current Eliminator (NCE) A 3-phase, low zero sequence impedance autotransformer, which when connected near to and in parallel with the harmonic generating non-linear loads (...